Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Hum Resour Health ; 17(1): 66, 2019 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-31412871

RESUMEN

BACKGROUND: This study contributes to a small but growing body of literature on how context influences employee turnover intention. We examine the impact of staff perceptions of supervisory leadership support for safety, teamwork, and mindful organizing on turnover intention. Interaction effects of safety-specific constructs on turnover intention are also examined. METHODS: Cross-sectional survey data were collected from nurses, allied health professionals, and unit clerks working in intensive care, general medicine, mental health, or the emergency department of a large community hospital in Southern Ontario. RESULTS: Hierarchical regression analyses showed that staff perceptions of teamwork were significantly associated with turnover intention (p < 0.001). Direct associations of supervisory leadership support for safety and mindful organizing with turnover intention were non-significant; however, when staff perceived lower levels of mindful organizing at the frontlines, the positive effect of supervisory leadership on turnover intention was significant (p < 0.01). CONCLUSIONS: Our results suggest that, in addition to teamwork perceptions positively affecting turnover intentions, safety-conscious supportive supervisors can help alleviate the negative impact of poor mindful organizing on frontline staff turnover intention. Healthcare organizations should recruit and retain individuals in supervisory roles who prioritize safety and possess adequate relational competencies. They should further dedicate resources to build and strengthen the relational capacities of their supervisory leadership. Moreover, it is important to provide on-site workshops on topics (e.g., conflict management) that can improve the quality of teamwork and consequently reduce employees' intention to leave their unit/organization.


Asunto(s)
Actitud del Personal de Salud , Intención , Reorganización del Personal/estadística & datos numéricos , Personal de Hospital/psicología , Adulto , Estudios Transversales , Femenino , Hospitales Comunitarios , Humanos , Relaciones Interprofesionales , Liderazgo , Masculino , Ontario , Grupo de Atención al Paciente
2.
Europace ; 17(3): 461-7, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25488957

RESUMEN

AIMS: The purpose of this study was to evaluate the outcomes of purely substrate-guided ventricular tachycardia (VT) ablation in patients with non-ischaemic dilated cardiomyopathy (NIDCM) and ischaemic cardiomyopathy (ICM) and the impact of acute procedural success on long-term outcome. METHODS AND RESULTS: One hundred and forty-two patients (65 ± 12 years old, 72% male) with ICM (n = 87) and with NIDCM (n = 55) underwent substrate-guided VT ablation. The ablation approach involved eliminating all LP regions and ablating all scar border zone regions with 10 or more out of 12 pace-matching. All patients were followed with regular implantable defibrillator interrogations for mean 641 ± 301 days. Complete acute success (no inducible VT) was achieved in 60 patients with ICM (69%) and in 29 patients with NIDCM (53%) (P = 0.03). Partial success (elimination of clinical VT only) was obtained in nine patients with ICM (10%) and in four patients with NIDCM (7%) (P = 0.14). Procedural failure (clinical VT still inducible) occurred in 18 patients within the ICM group (21%) and in 22 patients of the NIDCM (40%) (P = 0.04). Overall, 51 patients presented with recurrence of ventricular arrhythmias: 23 in the group with ICM (26%) and 28 in the group with NIDCM (51%) (P = 0.03). Long-term success was related to acute procedural outcome. CONCLUSIONS: Substrate-guided ablation is an effective approach in the treatment of VT with long-term outcome directly related to acute procedural success. Success rates are significantly lower in patients with NIDCM compared with those with ICM.


Asunto(s)
Cardiomiopatía Dilatada/etiología , Ablación por Catéter/métodos , Cicatriz/cirugía , Isquemia Miocárdica/complicaciones , Taquicardia Ventricular/cirugía , Anciano , Técnicas de Imagen Cardíaca , Estudios de Casos y Controles , Cicatriz/etiología , Técnicas Electrofisiológicas Cardíacas , Mapeo Epicárdico , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Recurrencia , Taquicardia Ventricular/etiología , Resultado del Tratamiento
3.
J Interv Card Electrophysiol ; 34(3): 303-10, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22406931

RESUMEN

PURPOSE: Pulmonary vein antrum isolation (PVAI) guided by intracardiac echocardiography and a roaming circular mapping catheter is an effective treatment modality for atrial fibrillation. Unfortunately, the complexity of this technique leads to long procedure times and high fluoroscopy exposure. Single-catheter multipolar ablation holds the promise to reduce these parameters. This study examined the effect of the conventional point-by-point PVAI with that of single-catheter multipolar ablation on the procedural characteristics and clinical outcomes of atrial fibrillation ablation. METHODS: Referred patients underwent PVAI guided by a magnetic-based 3D mapping (CARTO 3(®) System; group 1) or duty-cycled multipolar AF ablation using the pulmonary vein ablation catheter (PVAC, group 2) between June 2010 and May 2011. RESULTS: Data were analyzed from 19 patients in group 1 and 31 patients in group 2. There was no significant difference in the length of the procedure between the two groups (135 ± 26 vs 125 ± 25 min, P = 0.20). Patients who underwent ablation using PVAC spent significantly less time in the procedure room pre- and post-procedure than those who underwent conventional PVAI (205 ± 38 vs 179 ± 30 min, P = 0.02) and had a significantly shorter fluoroscopy exposure (50 ± 16 vs 36 ± 14 min, P = 0.003) and radiofrequency energy delivery time (54 ± 26 vs 32 ± 33 min, P = 0.02). No differences in safety and efficacy were seen between the groups. CONCLUSIONS: Single-catheter multipolar AF ablation was associated with significantly lower fluoroscopy duration, radiofrequency energy delivery time, and the time the patient spent in the procedure room before and after ablation, although measured short-term clinical outcomes were similar.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Ecocardiografía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ultrasonografía Intervencional , Técnicas Electrofisiológicas Cardíacas , Femenino , Fluoroscopía , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 22(11): 1206-14, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21668562

RESUMEN

INTRODUCTION: Pulmonary vein antrum isolation (PVAI) is an accepted treatment for atrial fibrillation (AF) refractory to medical therapy. The purpose of this study was to identify the patient, procedural, and follow-up factors associated with arrhythmia recurrences following PVAI. METHODS AND RESULTS: Clinical data were prospectively collected on all 385 consecutive patients who had 530 PVAI (age 58 ± 11 years, 63% paroxysmal AF-PAF, follow-up 2.8 ± 1.2 years) between February 2004 and March 2009. ECGs were recorded at each follow-up visit with Holter monitoring 1, 3, 6, and 12 months following PVAI and every 6 months thereafter. Recurrences < 3 months post-PVAI were defined as early, 3 months-1 year post-PVAI as late, and > 1 year post-PVAI as very late. Relationship between predictor variables and outcomes was modeled using Cox proportional hazards analysis. Late recurrences occurred in 42% with a lower rate among PAF versus non-PAF patients (39% vs 56%, P = 0.001). Of the 256 patients with ≥ 1-year follow-up, 121 (47%) had no arrhythmia off antiarrhythmic drugs (AADs) 1 year post-PVAI; 36 (30%) of these had a very late recurrence. In multivariate analysis, non-PAF, hypertension, and prior AAD failure predicted recurrence. When entered into the model, early recurrences remained the only predictor of late recurrences. CONCLUSION: Patients with non-PAF, hypertension, and prior failure of multiple AAD were more likely to experience arrhythmia recurrence post-PVAI. Early recurrences were the strongest predictor of late recurrences. Late and very late recurrences following PVAI were common and should be considered when planning long-term AF patient management.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Canadá , Ablación por Catéter/efectos adversos , Supervivencia sin Enfermedad , Electrocardiografía Ambulatoria , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Recurrencia , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
J Interv Card Electrophysiol ; 30(3): 233-40, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21253840

RESUMEN

PURPOSE: Pulmonary vein antrum isolation (PVAI) guided by intracardiac echocardiography and a roaming circular mapping catheter is an effective treatment modality for atrial fibrillation. Unfortunately, the complexity of this technique leads to long procedure times and high fluoroscopy exposure. This study examined the effect of two different mapping systems on the procedural characteristics and clinical outcomes of PVAI for atrial fibrillation. METHODS: Referred patients underwent PVAI using a magnetic-based 3-dimensional (3-D) mapping (CARTO® System; group 1), a current-based system (EnSite NavX™; group 2), or fluoroscopy without 3-D mapping (group 3) between February 2004 and November 2009. RESULTS: Data were analyzed from 71 patients in group 1, 165 patients in group 2, and 197 patients in group 3. Baseline characteristics and measured long-term outcomes did not differ between the groups. Although patients in group 1 were more likely to undergo a concurrent flutter ablation (P = 0.01), they had significantly shorter procedure time, fluoroscopy time, and radiofrequency energy delivery time compared with group 2 and 3 patients. No difference was detected among the groups with respect to recurrence, mean time to recurrence, or number of PVAI procedures. CONCLUSIONS: Use of a magnetic-based 3-D mapping system, which allows precise spatial localization of the ablation catheter, was associated with significantly lower procedure time, fluoroscopy duration, and radiofrequency energy delivery time during catheter ablation for atrial fibrillation compared with a current-based system and ablation performed without 3-D mapping, although measured short- and long-term clinical outcomes were similar.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Fluoroscopía/instrumentación , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/instrumentación , Fibrilación Atrial/fisiopatología , Distribución de Chi-Cuadrado , Electrocardiografía , Femenino , Humanos , Imagenología Tridimensional/instrumentación , Masculino , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
6.
Heart Rhythm ; 5(8): 1127-33, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18675223

RESUMEN

BACKGROUND: Atrial fibrillation (AF) ablation guided by complex fractionated electrograms (CFE) has been described, but the spatial and temporal stability of the electrograms (EGMs) has been questioned. OBJECTIVE: The purpose of this study was to prospectively assess the spatial and temporal stability of CFE in patients with persistent AF. METHODS: Twenty-four patients were studied. For 12 patients, two high-density CFE maps were performed during AF at baseline (0 minute) and 20 minutes later using the EnSite NavX system. Six-second bipolar EGMs were collected throughout the left atrium (LA) using a circular mapping catheter. Automated software measured the time between discrete local EGM deflections yielding a mean local cycle length (CL). EGMs with mean CL <120 ms were considered CFE. The LA was divided into six regions. Spatial distribution of EGMs at 0 and 20 minutes was compared in each region across three different CL ranges (A = 50-120 ms, B = 121-200 ms, C = 200-500 ms). The 0- and 20-minute CFE maps were directly superimposed offline in MATLAB, and the mean CL value for each point that was sampled in both maps was compared in each CL range (A-C). For the other 12 patients, repetitive measurements (1-minute intervals for 5 minutes) of mean CL were obtained at a sample point for each CL range (A-C) in each patient and compared for consistency. RESULTS: A total of 324 +/- 65 points were collected per map. Globally in the LA, the distribution of CLs did not change from 0 to 20 minutes (A: 47.1% vs 45.0%; B: 35.3% vs 36.5%; C: 16.0% vs 16.9%; P = .6). The CL distribution in each of the six regions of the LA also did not change significantly from 0 to 20 minutes. There was no significant change in repetitive CL measures for range A (mean DeltaCL 12 +/- 4 ms, P = .4). However, there was significant variation over 5 minutes for ranges B and C (mean DeltaCL 39 +/- 19 ms and 48 +/- 22 ms, respectively, P <.05 for both). Superimposing maps showed 74.7% point-to-point match for range A, 39.3% for range B, and 14.2% for range C (within 30 ms), with a significant correlation seen only for range A (r = 0.82, P <.001). CONCLUSION: CFE show a high degree of spatial and temporal stability. Greater temporal variation is seen in progressively longer CL regions that are outside of the CFE region of interest.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/terapia , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter , Electrocardiografía , Fibrilación Atrial/diagnóstico por imagen , Mapeo del Potencial de Superficie Corporal/instrumentación , Ecocardiografía , Electrocardiografía/métodos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Técnicas Electrofisiológicas Cardíacas/métodos , Femenino , Humanos , Masculino , Potenciales de la Membrana , Persona de Mediana Edad , Estudios Prospectivos , Volumen Sistólico , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA